Zoll PD 2000 Defibrillator
AJANTA EXPORT INDUSTRIES are manufacturer, supplier and Exporter of Zoll PD 2000.The ZOLL PD 2000 Advisory Defibrillator/Pacemaker is the first device designed as a completely integrated system for early defibrillation and advanced cardiac life support in the hospital. The built-in ventricular fibrillation detection system eliminates adapters and a "paddle free" electrode system is easily applied to speed shock delivery and external pacing. Standardized controls make it ideal for the hospital planning implementation of early defibrillation to improve outcomes from cardiac arrest. This small and lightweight unit is the most versatile hospital defibrillation system available today. The PD 2000 is equally suited for general floor use by noncritical care BLS trained staff and ACLS code teams for defibrillation, external pacing and transport. New state-of-the-art modular AC power and rapid battery recharging allow the PD 2000 to meet the needs of every hospital area. Its easily exchangeable low cost lead acid battery system provides unequaled crash-cart up time and improved quality in device maintenance and readiness. No other unit provides a hospital with the inherent flexibility of the ZOLL PD 2000 Advisory Defibrillator/Pacemaker.
Features:
Innovative features:
Large Monitor
Non-fade monitor
ECG monitor
Strip recorder
AC power supply for stationary use
Specifications:
Type: VVI demand; asynchronous (fixed rate)
when used without ECG leads
Pulse Type: Rectilinear, constant current
Pulse Duration: 40 milliseconds.
Pulse Amplitude: Variable to 140 mA
Pacing Rate: Variable from 30 to 180 PPM
Output Protection: Fully defibrillator-protected and isolated
Pacer On: Message display on monitor
Defibrillator
Waveform: Damped sinusoid
Output Energy
Delivered: Selectable at 2, 3, 5, 7, 10, 20, 30, 50,100, 150, 200, 300, 360 joules
Charge Time: Less than 10 seconds
Delivered Energy
Display: CRT monitor displays delivered energy
Synchronized Mode: Synchronizes defibrillator pulse to patients R-wave. SYNC message
displayed on monitor. Marker on monitor and on recorder paper identifies R-wave
Internal Paddles: Output limited to 50 joules when internal paddles are connected. Discharge from paddles
Charge Controls: Control on apex paddle and front panel.
Paddles: Standard paddles are anterior/anterior adult and pediatric. Adult paddles slide off to expose pediatric paddles
Defibrillation Electrodes: Specifically designed ZOLL Multi- Function Electrodes used in anterior/anterior or anterior/posterior positions; packaged in pairs
Integral Defibrillator Tester: Integral circuitry allows complete test
of defibrillator charge and discharge without removing paddles from storage wells. Identical circuitry allows complete test of unit configured with multifunction cable
Defib On: Message display on monitor
Monitor and Display
Patient Connection: Via 3-lead ECG cable, paddles, and elec trodes. Selectable by front panel switch
Input Protection: Fully defibrillator-protected. Special circuit prevents distortion of ECG by pacer pulse
Bandwidth: .5 40 Hz (3dB) standard
Display Format: Nonfade, moving trace with freeze capability
Monitor On: Message display on monitor
Screen Type: High-resolution CRT display
Screen Size: 5 inches diagonally (108 mm x 85 mm viewing area)
![]() |